Hardware Connection and Interface Description

UNO Q Connection​

Connect with Power Off

Before installing or removing the UNO Q, the carrier board, and the camera cable, shut down the system and disconnect all power. Do not hot-plug the JMEDIA, JMISC, or camera cable.

  1. Place the screen on a support surface that will not press against and damage the panel, exposing the carrier board on the back.

  2. Align the JMEDIA and JMISC connectors of the UNO Q and the carrier board, and stack and connect them in the direction shown in the figure.

    Stacking connection direction of the UNO Q and the carrier board on the back of the screen

    After confirming that the connector positions are correct, press evenly to avoid misalignment or forcing insertion at an angle.

    Stacking of the UNO Q and the carrier board on the back of the screen

  3. Choose one of the following methods to power the UNO Q. Both the power port and the cable must meet the 5 V / 3 A requirement:

    • Power adapter supply: Connect the power adapter to the UNO Q's USB-C port.

      Power connected to the UNO Q's USB-C interface

    • Computer USB port supply: Use a USB-C cable that supports data transfer to connect the UNO Q to a computer, providing both power and data communication.

Camera Connection​

This product is equipped with two 22 PIN CSI camera interfaces, and only supports connecting IMX219 camera modules. If you do not need to use a camera, you can skip this step.

  1. Shut down the system, disconnect the power, and remove the UNO Q mainboard.

  2. Check the CSI interface pin definitions, and confirm the interface specifications and contact orientation of the camera module and cable.

    CSI interface pin definitions of this product and the positions of pins 1 and 22

  3. Correctly insert the cable into the CSI interface and lock the connector. After confirming that the connection is correct, reinstall the UNO Q mainboard and connect the power.

    info

    Note: The image is for connection reference only. The specific connection direction of the cable should be based on the interface definition of the camera module, to avoid reverse connection or misalignment.

    External camera connection illustration; both the UNO Q and the camera need to be purchased separately